High and low temperature damp heat test box cleans five ways to save time and effort

According to the feedback from the Beijing Yashilin After-sales Service Department, we have come to the big data. Most of the customer's main inquiries are basically related to how to clean the equipment after use, how to maintain it, and the temperature can not fall down. So today we will talk about the cleaning method after using the high and low temperature damp heat test chamber!

What we need to do after the high and low temperature damp heat test chamber test is actually very simple, only five steps, as follows:

(1) High and low temperature damp heat test chamber humidifier maintenance: The water storage tank should be replaced once a month to ensure clean water, and the water pan should be cleaned once a month to ensure smooth water flow.

(2) Remove the high and low temperature damp heat test chamber condenser. The condenser should be regularly maintained monthly. Use a vacuum cleaner to inhale the dust attached to the condenser heat dissipation mesh or use a high pressure air spray to reduce dust.

(3) High-low temperature damp heat test chamber wet ball gauze replacement: remove the wet ball gauze from the high and low temperature damp heat test box. If the gauze becomes yellow and hard, it can be disposed of directly. If the gauze is still intact, it can be cleaned and dried. Continue to use, this can save gauze and protect the humidity sensor, then wipe the steam or stain in the work chamber with a clean rag. If the studio is large and inconvenient to clean manually, you can also directly use the high and low temperature alternating heat and humidity test chamber. High temperature function, set 50 degrees high temperature baking for half an hour.

(4) Inspection and adjustment of the wet water level of the high and low temperature test chamber: The water level of the water storage tank should not be too high, so that the water overflows the water storage cylinder or the water is too low to make the wet ball gauze absorb water abnormally, which affects the accuracy of the wet bulb. The water level is approximately six minutes full. The water level of the water reservoir can be adjusted to adjust the level of the water tank.

(5) The high-low temperature damp heat test chamber should be removed before the operation. The power distribution room should be cleaned at least once a year, and the vacuum cleaner can be used to clean the indoor dust. The outer box must be cleaned once, for a year or more, and then wiped with soapy water.